A gate evaluation of the sources of error in quantitative 90Y PET

Résumé

Purpose: Accurate reconstruction of the dose delivered by 90Y microspheres using a postembolization PET scan would permit the establishment of more accurate dose–response relationships for treatment of hepatocellular carcinoma with 90Y. However, the quality of the PET data obtained is compromised by several factors, including poor count statistics and a very high random fraction. This work uses Monte Carlo simulations to investigate what impact factors other than low count statistics have on the quantification of 90Y PET. Methods: PET acquisitions of two phantoms—a NEMA PET phantom and the NEMA IEC PET body phantom-containing either 90Y or 18F were simulated using GATE. Simulated projections were created with subsets of the simulation data allowing the contributions of random, scatter, and LSO background to be independently evaluated. The simulated projections were reconstructed using the commercial software for the simulated scanner, and the quantitative accuracy of the reconstruction and the contrast recovery of the reconstructed images were evaluated. Results: The quantitative accuracy of the 90Y reconstructions were not strongly influenced by the high random fraction present in the projection data, and the activity concentration was recovered to within 5% of the known value. The contrast recovery measured for simulated 90Y data was slightly poorer than that for simulated 18F data with similar count statistics. However, the degradation was not strongly linked to any particular factor. Using a more restricted energy range to reduce the random fraction in the projections had no significant effect. Conclusions: Simulations of 90Y PET confirm that quantitative 90Y is achievable with the same approach as that used for 18F, and that there is likely very little margin for improvement by attempting to model aspects unique to 90Y, such as the much higher random fraction or the presence of bremsstrahlung in the singles data.

Domaines

Cancer
Fichier sous embargo
Fichier sous embargo
Date de visibilité indéterminée
Loading...

Dates et versions

inserm-01523817 , version 1 (17-05-2017)

Identifiants

Citer

Jared Strydhorst, Thomas Carlier, Arnaud Dieudonné, Maurizio Conti, Irène Buvat. A gate evaluation of the sources of error in quantitative 90Y PET. Medical Physics, 2016, 43 (10), pp.5320. ⟨10.1118/1.4961747⟩. ⟨inserm-01523817⟩
126 Consultations
2 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More