Utilization of matched pulses to improve fault detection in wire networks

Résumé

A new concept to fault detection in wire networks, based on the properties of time reversal, is presented. The method, called the Matched Pulse approach (MP), propose to adapt the testing signal to the analyzed network, instead of using a predefined signal, as opposed to existing reflectometry methods. Through mathematical study and numerical simulations, we show the benefits of this technique. A physical interpretation is also presented to better understand the proposed approach.
Fichier principal
Vignette du fichier
final_paper_53.pdf (230.44 Ko) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)
Loading...

Dates et versions

hal-00446436 , version 1 (18-11-2010)

Identifiants

  • HAL Id : hal-00446436 , version 1

Citer

Layane Abboud, Andrea Cozza, Lionel Pichon. Utilization of matched pulses to improve fault detection in wire networks. 2009 International Conference on ITS Telecommunications, Oct 2009, Lille, France. pp.PHY IV - 3. ⟨hal-00446436⟩